Fast Electrical Fault Finding · Same-Day Response · Kettering & Northamptonshire

RCD Keeps Tripping in Kettering? We'll Find the Fault Fast.

A constantly tripping RCD usually points to a deeper issue. Rather than guess or keep resetting it, it needs a proper diagnosis. We diagnose methodically and aim to identify the likely fault as efficiently as possible.

Methodical
Fault Diagnosis
Same
Day Response
NAPIT
Registered
Fixed
Pricing
NAPIT Registered
Same-Day Response
No Guesswork
Fixed Pricing
Workmanship Guaranteed
What's Happening

Why Is My RCD Tripping?

A constantly tripping RCD is one of the most disruptive electrical faults you can have. It usually points to a deeper issue — a faulty appliance, damp in a fitting, damaged cable, or a wiring fault hidden somewhere in the circuit.

Rather than guess or keep resetting it, it needs a proper diagnostic. At Entigen, we specialise in accurate electrical fault finding across Kettering, Barton Seagrave, Burton Latimer and surrounding areas. Many straightforward RCD faults can be narrowed down quickly with proper test equipment and step-by-step isolation.

Got an urgent fault?

Message our emergency triage line with your location and a photo of the consumer unit. We'll review your situation and respond as quickly as possible. Emergency electrician →

Consumer unit RCD switches — fault diagnosis by Entigen Kettering

Common Causes of a Tripping RCD

Faulty appliances — kettles, washing machines, dishwashers and garden tools are among the most common culprits for nuisance RCD trips.
Damaged or crushed wiring — cables pinched under floorboards, screws through conduit, or rodent damage causing insulation breakdown.
Water ingress — outdoor sockets, garden lights, bathroom fittings or condensation entering an IP-rated fitting below the required rating.
Neutral-to-earth faults — a wiring defect where neutral and earth conductors are bridged, causing the RCD to detect a leakage current and disconnect.
Ageing, deteriorated circuits — older rubber or cloth-insulated wiring breaking down with age and causing leakage to earth.
Faulty downlights or transformers — older 12V halogen transformers and LED drivers can develop faults that cause the RCD to trip.

Also: incorrect DIY additions, unsafe modifications, damaged extension leads and overloaded circuits.

How We Fix It

How We Diagnose & Fix an RCD Fault

No guesswork, no unnecessary replacements — just a clear diagnosis and a safe fix. Here's our systematic approach:

01
Circuit Isolation
We isolate each circuit one by one to pinpoint exactly which circuit is causing the RCD to trip — narrowing the fault to a specific area of the installation.
02
Appliance Testing
Appliances on the affected circuit are tested individually. Faulty appliances are identified and removed from the equation, confirming whether the issue is equipment or wiring.
03
Insulation Resistance Testing
Using a calibrated Megger MFT1741, we carry out insulation resistance tests on individual circuits to detect cable breakdown, moisture or wiring defects.
04
Visual Inspection
Physical inspection of suspect fittings, junction boxes and the consumer unit. Common points include outdoor sockets, bathroom fittings, and consumer unit wiring.
05
Safe Repair & Certification
Root cause identified, fault repaired safely and tested to BS 7671 standard. No guesswork, no unnecessary circuit replacements. You receive a clear explanation and, where required, certification.
What Customers Say

Trusted Across Kettering for RCD Faults

★★★★★

"Had an issue with our fuse board in Kettering that kept tripping. Ben came out today and had us back up and running in no time. Nice bloke, explained everything properly and was honest with pricing."

Mark Hollis — Google Review
★★★★★

"After being recommended by a friend, Ben came around to quote for one job and do some electrical maintenance. Very professional, thorough and polite. Did a great job."

Bryan Lade — Google Review
★★★★★

"Ben was amazing — onsite within two hours of me contacting him, which included a quote sent beforehand to avoid any surprises. Highly recommended."

Sarah Billett — Google Review
Fault Support

If your issue sounds similar, these pages may help you understand the fault before getting in touch.

If Your RCD Keeps Tripping, It Won't Fix Itself.

Contact Entigen for reliable RCD diagnosis anywhere in Kettering and Northamptonshire. We diagnose methodically and aim to identify the likely fault as efficiently as possible.

Mon–Fri 8:30–16:30 · NAPIT Registered · Cost Confirmed Before Attendance